Description
The Battery Charging and Discharging Tester is a specialized device that both charges and discharges lead-acid battery banks under controlled conditions, enabling accurate capacity evaluation and battery maintenance. It supports multi-stage charging (constant-current, constant-voltage, float/trickle) as well as controlled discharge tests, with real-time monitoring of voltage, current, and time. This tester logs data for analysis and provides safety protections (over-current, over-temperature, etc.) to ensure reliable operation. It is ideal for industrial UPS systems, telecom battery rooms, substations, and EV battery recycling scenarios where both charging and discharge testing are required.
Parameters
| DC10-300V Battery Charging& Discharging Tester |
|||||||
| Voltage monitoring range | DC0-300V | ||||||
| Discharge current | 0-80A | 0-120A | 0-120A | ||||
| Charging current | 1-60A | 1-60A | 1-120A | ||||
| Instrument Functionality |
|||||||
| Display | 7-inch LCD touch screen with 1024 x 800 resolution | ||||||
| Voltage measurement accuracy | ±0.5%FS+0.1V | ||||||
| Current measurement accuracy | ±1%FS+0.1A | ||||||
| Discharge current display accuracy | 0.1A | ||||||
| Cell voltage display accuracy | 0.01V | ||||||
| Cell voltage monitoring function | Communicat distance up to 100 m or more,Compatible with 2V/4V/6V/12V single battery voltage monitoring.
Each monitoring module can monitor 12 cells at the same time,the high limit can monitor 300 batteries. |
||||||
| Data storage | Internal 32G TF storage, external 16G micro-USB card reader | ||||||
| Data communication | RS485、USB | ||||||
| Working mode | Activation, constant-current, constant-voltage, float-charge | ||||||
| Protection performance (LCD display reminder + buzzer alarm) |
|||||||
| Host protection function | Over-temperature, over-current, current runaway trigger shutdown protection | ||||||
| Reverse connection protection | Reverse polarity audible and visual alarms | ||||||
| Abnormal protection | Power line drop, mains cable drop | ||||||
| Over temperature protection | Built-in temperature sensing probe, temperature over 75°C, the device automatically stops discharging | ||||||
| emergency stop | External open circuit breaker for emergency shutdown protection | ||||||
| Working environment |
|||||||
| Cooling mode | Forced air cooling | ||||||
| Temperature | Operating temperature : -5~50℃, Storage temperature : -40~70℃. | ||||||
| Humidity | Relative humidity : 0~90%(40±2℃) | ||||||
| Altitude | Available below 4000m | ||||||
| Power supply |
|||||||
| Voltage |
Supply voltage: AC 220V (-20%~+30%), frequency: 45~65Hz. Charging input: AC220V (-20%~+30%) |
||||||
| Withstand voltage | Input-shell: 2200Vdc 1min / Input-output: 2200Vdc 1min / Output-shell: 700Vdc 1min | ||||||